Battery Impact Chamber RS-6010C

Battery Impact Chamber RS-6010C

Battery Impact Chamber RS-6010C

The testing battery sample is placed on a flat surface with a 15.8 earth 0.2mm (5/8 inch) diameter bar placed crosswise over the center of the specimen. A 9.1kg or 10kg weight is dropped onto the sample from a certain height (610mm or 1000mm or 1500mm). Cylindrical or square cells are subjected to the impact test with their longitudinal axis parallel to the plane and perpendicular to the longitudinal axis of the steel column. The longest axis of the square cell is perpendicular to the sub-steel column, and the most heavenly surface is perpendicular to the direction of impact, and each cell is subjected to only one impact test.

Product parameter  
Drop Weight 9.1 kg x 0.46 kg (20 x 1 lb), 10 kg (optional)
Impact height 200~1500mm (Height can be set freely in the touch panel) Maximum test height 1500mm.
Height display Displayed on the touch panel, accurate to 1mm
Impact method Lift the ball to a certain height and release it, the ball will fall freely in the vertical direction.
Crossbar 15.8 earth 0.2mm (5/8 inch) steel rod.
Material Inner box material: SUS#304 stainless steel plate, outer box material: cold rolled plate baking paint treatment
Air vent Located at the back of the box, diameter 120mm, external diameter 110mm exhaust duct
Controller and test box remote wire control distance 10m
Maximum cell size W350*D350*H300mm or customized other specifications
Viewing Window W380mm*H300mm
Power Supply 1 ∮ ,AC220V,5A
Weight Approx. 380kg
Main unit volume W850xD785xH2400mm(without controller)
Control cabinet volume W400xD450xH1400mm(without controller)