model
|
RS-6006GDW
|
Test capacity
|
10 kN, 20 kN, 50 kN (optional)
|
Equipment precision
|
Level 0.5
|
Temperature box parameters
|
Temperature range: -20℃ ~ + 85℃ (adjustable)
Temperature fluctuation degree: ± 2.0℃
Temperature deviation: ± 2.0℃
Temperature uniformity: ± 2.0℃
Rise / cooling rate: 1℃ / min (no-load, nonlinear)
|
External box material
|
Cold-rolled steel plate, the thickness of 1.2MM, double-sided spraying treatment
|
Internal box material
|
Using SUS304 # stainless steel plate, the thickness is 1.0MM, the whole full welding treatment, to ensure the sealing performance of the inner box, the bottom of the strengthened design, the inner box can easily clean and dispose of the battery explosive decomposition
|
camera
|
External configuration of 800W HD camera, brand Hikvision
|
safety function
|
Explosion-proof, pressure relief, forced smoke exhaust
|
Air supply mode
|
External high temperature air inlet, exhaust outlet, with closed valve
|
Force value range
|
0.1~100%(capacity)
|
Force value accuracy
|
≤±0.5%FS
|
Displacement range
|
0~350mm
|
Displacement resolution
|
0.001mm
|
Displacement accuracy
|
≤±0.5%
|
Spin test speed
|
0.01-80 mm/s (continuously adjustable)
|
Squeeze test speed
|
0.01-30 mm/s (continuously adjustable)
|
Speed resolution
|
0.001mm/s
|
Speed control accuracy
|
≤±0.5%
|
Squeeze fixtures
|
A, circular extrusion head: diameter 200mm, thickness 20mm;
B. Rectangular extrusion head: 200 * 400mm, 20mm thickness;
C. Ball extrusion head: diameter 15 / 20 / 25 / 30mm, length 90mm; diameter 150 / 180mm, length 300mm;
D, R-type extrusion head: radius R75mm, width 300mm, length 300mm;
Material is made of 304 # stainless steel
|
draw point
|
ø 1, ø 3, ø 5, ø 6, ø 8mm, taper 30,45,60 tungsten steel needle
|
Voltage collection channel
|
A. Acquisition channel: 3 channels;
B, Voltage acquisition range: 0~10V
And c. Voltage resolution: 0.1 mV
D, voltage accuracy: ± 0.069%
|
Temperature collection channel
|
A. Acquisition channel: 10 channel;
B. Temperature acquisition range: 0~1000℃
C., Temperature resolution: 0.1℃
D, Temperature accuracy: ± 2℃
E, replaceable thermocouple, quick replacement
|
Frequency of data acquisition
|
1000Hz
|
Test return speed
|
1~80mm/s
|
Downtime method
|
Force value, deformation, voltage, temperature, temperature rise rate, can be arbitrarily combination
|
safe guarding
|
Mechanical limit, force value overload protection, emergency stop switch
|
source
|
AC380V 50Hz
|
Emergency-stop response time Emergency stop time
|
100ms
|