High and low temperature battery extrusion & needle testing machine MODEL: RS-6006 GDW

High and low temperature battery extrusion & needle testing machine MODEL: RS-6006 GDW

High and low temperature battery extrusion & needle testing machine MODEL: RS-6006 GDW

use:

It is used for extrusion & acupuncture test of battery and battery module in high and low temperature environment. It has video monitoring function and can automatically save video and reproduce the test process.

model

RS-6006GDW

Test capacity

10 kN, 20 kN, 50 kN (optional)

Equipment precision

Level 0.5

Temperature box parameters

Temperature range: -20℃ ~ + 85℃ (adjustable)

Temperature fluctuation degree: ± 2.0℃

Temperature deviation: ± 2.0℃

Temperature uniformity: ± 2.0℃

Rise / cooling rate: 1℃ / min (no-load, nonlinear)

External box material

Cold-rolled steel plate, the thickness of 1.2MM, double-sided spraying treatment

Internal box material

Using SUS304 # stainless steel plate, the thickness is 1.0MM, the whole full welding treatment, to ensure the sealing performance of the inner box, the bottom of the strengthened design, the inner box can easily clean and dispose of the battery explosive decomposition

camera

External configuration of 800W HD camera, brand Hikvision

safety function

Explosion-proof, pressure relief, forced smoke exhaust

Air supply mode

External high temperature air inlet, exhaust outlet, with closed valve

Force value range

0.1~100%(capacity)

Force value accuracy

≤±0.5%FS

Displacement range

0~350mm

Displacement resolution

0.001mm

Displacement accuracy

≤±0.5%

Spin test speed

0.01-80 mm/s (continuously adjustable)

Squeeze test speed

0.01-30 mm/s (continuously adjustable)

Speed resolution

0.001mm/s

Speed control accuracy

≤±0.5%

Squeeze fixtures

A, circular extrusion head: diameter 200mm, thickness 20mm;

B. Rectangular extrusion head: 200 * 400mm, 20mm thickness;

C. Ball extrusion head: diameter 15 / 20 / 25 / 30mm, length 90mm; diameter 150 / 180mm, length 300mm;

D, R-type extrusion head: radius R75mm, width 300mm, length 300mm;

Material is made of 304 # stainless steel

draw point

ø 1, ø 3, ø 5, ø 6, ø 8mm, taper 30,45,60 tungsten steel needle

Voltage collection channel

A. Acquisition channel: 3 channels;

B, Voltage acquisition range: 0~10V

And c. Voltage resolution: 0.1 mV

D, voltage accuracy: ± 0.069%

Temperature collection channel

A. Acquisition channel: 10 channel;

B. Temperature acquisition range: 0~1000℃

C., Temperature resolution: 0.1℃

D, Temperature accuracy: ± 2℃

E, replaceable thermocouple, quick replacement

Frequency of data acquisition

1000Hz

Test return speed

1~80mm/s

Downtime method

Force value, deformation, voltage, temperature, temperature rise rate, can be arbitrarily combination

safe guarding

Mechanical limit, force value overload protection, emergency stop switch

source

AC380V 50Hz

Emergency-stop response time Emergency stop time

100ms